The assessment of unreinforced masonry structures is difficult to undertake in practice. A structural engineer is usually confronted with a standing, apparently competent, structure that seems to defy most of the rules of structural behavior, as incorporated in modern building codes. The engineer must then choose between reinforcing the structure according to a modern understanding of material strength and structural behavior or trying to make sense of the behavior and anticipated strength of the structure on a more fundamental level. A fundamental structural assessment, although it involves a considerable amount of effort in analysis and in furthering the understanding of masonry behavior, is the more rewarding. This course of action is consistent with the principles of historic preservation, as summarized in the Secretary of the Interior's Standards for the Treatment of Historic Properties. The following manual is intended to introduce a sympathetic structural engineer to some of the principles of unreinforced masonry and especially to provide some basic instructions in preparing a model of such a structure for analysis, using widely available, modern tools for structural analysis. In Section 2, the assessment of two dimensional arches is introduced. This section begins with an elaboration of the competing issues of code compliance and rational assessment as described in the introductory remarks above. Section 3 covers the assessment of three-dimensional masonry vaults using widely available structural analysis software. Case studies, illustrating the procedure recommended for the assessment of masonry structures are provided in Sections 4 through 6.

Twitter It!

Related posts:

  1. Mechanical Anchor Strength in Stone Masonry (2008-05) he main objective of this research project is to better...
  2. Swelling Mechanism in Clay-Bearing Sandstones (2007-09) Swelling clays in stone can generate damaging stresses during a...
  3. Manual on Conservation Methodology for Historic Buildings and Structures (1997-07) Herein, basic Conservation and Preservation concepts would be pragmatically explained...
  4. Nondestructive Evaluation Methods for Historic Structures APT and NCPTT partnered to present nondestructive evaluation methods for...
  5. Load Paths in Historic Truss Bridges (2004-25) The stiffening effect of existing features on historic truss bridges...


Tags: , , , ,
 
 

Leave a Comment

 
  • Categories
  • Tags
  • Blog
 
 
Email icon
 
 
 
Email: ncptt@nps.gov
Phone: (318) 356-7444 · Fax: (318) 356-9119

NCPTT - National Center for Preservation Technology and Training
645 University Parkway
Natchitoches, LA 71457

Jump to Top